Porchy

Cowboys of Moo Mesa PAL dump added

 PAL Updates  Comments Off on Cowboys of Moo Mesa PAL dump added
Sep 272015
 

I dumped and added the PAL20L10 device (055373) from a Cowboy Moo Mesa PCB today.
The board doesn’t work so it is marked as untested and would appreciate any feedback on this one.

 Posted by at 6:26 pm

NANAO MS9-29S chassis repair log

 Monitor Repair Log, Repair Logs  Comments Off on NANAO MS9-29S chassis repair log
Sep 242015
 

Had this chassis for a long time sat in my loft. Its never worked properly and testing it now it doesn’t do anything.
prework
underside

Taking a good look at the chassis showed that quite a few capacitors had been leaking and testing random ones with the ESR tester revealed plenty more bad ones.
As it was in a poor state and also seeing as it is my first attempt at a monitor repair I opted to replaced pretty much every cap I could and do a clean up along the way.

I removed all the caps and tested each one that came out. Here is a list of the ones I found to be bad:
C958 – 47uF 16v
C956 – 680uF 10v
C457 – 10uF 50v
C459 – 22uF 50v
C561 – 47uF 16v
C451 – 22uF 50v
C222 – 22uF 50v
C201 – 47uF 16v
C203 – 47uF 16v
C955 – 180uF 25v
C953 – 47uF 160v
C513 – 10uF 250v
The electrolytic capacitor on the neck board was also bad.
Also found resister R585 (120k ohm) was damaged.

leaked
I ordered up the caps and cleaned up the PCB.
cleaned

I then turned my attention to the remote board.
remote1

This had two pots missing but had a couple of different ones hacked in their place and the smoothing capacitor was also leaking. I found some 10k Alps potentiometers on eBay so ordered a couple of those too.
The existing pots look in bad shape but they check out OK and operate quite smoothly so ill leave them alone for now.
remote2

A few days later all my stuff had arrived from Mouser and I was ready to put this thing back together.
done

I fitted it back into my spare 29″ tube and fired it up for the first test.

With a bit of tweaking I got the decent picture. The photo doesn’t really do it justice but I’m pleased with the results.
picture1

picture2

 Posted by at 11:59 am

Logic Probe testing

 General  Comments Off on Logic Probe testing
Sep 112015
 

This is something I’ve wanted to do for a while but never got around to.
The following is a mix of my personal thoughts and findings. I realise others will have the same equipment and the operation of these will likely differ.
This post is in no way a “What to buy” guide. It is meant to show how three different probes work at different voltage levels.

I’ve got three logic probes but only ever use one of them as I really like it but is it giving me the most accurate reading?
Lets take a look

So here are what I’ve got.
IMAG1589

Top one is a Tenma branded one (also seen this under different brand names). This is my probe of choice.
Second one is an unbranded one. Used this once and it feels really cheap in hand but it does have a buzzer in it to accompany the LED’s which is nice.
Lastly is an RS branded one. This is a recent eBay purchase bought mainly for this write-up.

First off, lead length.
There is nothing worse than being restricted but short leads when probing around a board.
Tenma = 58cm
Unbranded = 146cm
RS = 171cm

So my probe of choice has the shortest lead length. I must admit it has hindered me in the past.

To test the logic thresholds I used my programmable PSU and used the outputs that have a common ground.
Here are the ‘official’ threshold levels according to Wikipedia for TTL and CMOS (assumming VCC = +5v).
logic levels

The pictures below show the voltage at which the LOW LED goes OFF and the voltage at which the HIGH LED comes on.
Lets look at the Tenma probe to start with.
This probe only supports TTL logic levels where as the other two can switch between TTL and CMOS.

NOTE: You want to be looking at the smaller voltage settings at the bottom (under ‘Set’). This is the actual voltage settings and was checked for accuracy with a Fluke multimeter.

LOGIC LOW THRESHOLD (TTL)
Tenma Low_on

LOGIC HIGH THRESHOLD (TTL)
Tenma High_on

As you can see the LOW level begins to show around 0.1v below the stated thresholds. Not too bothered about that. Whats more worrying is the HIGH trigger point, its nearly 1v out of spec.

Next up is the unbranded probe

LOGIC LOW THRESHOLD (TTL)
TTL-UB Low_off

LOGIC HIGH THRESHOLD (TTL)
TTL-UB High_on

This has similar LOW trigger levels as the Tenma one and the HIGH trigger is around 0.7v lower bringing it nearer to the thresholds stated. Not too bad.

Finally the RS branded probe. The pictures are pretty useless here as the low brightness level of the probe at these voltages make it difficult to capture on camera but its there.
LOGIC LOW THRESHOLD (TTL)
TTL-RS Low_off

LOGIC HIGH THRESHOLD (TTL)
TTL-RS High_on

Results are very positive for this probe on the TTL setting.

Next I test the CMOS setting. As the Tenma cannot support CMOS it is obviously excluded from this test.
Unbranded first.

LOGIC LOW THRESHOLD (CMOS)
CMOS-UB Low_off

LOGIC HIGH THRESHOLD (CMOS)
CMOS-UB High_on

The LOW trigger is a bit low here but the HIGH is pretty good.
Now for the RS probe. Once again the pictures are pretty rubbish as the low level of the LED doesnt really show up on the camera but I assure you it is there.

LOGIC LOW THRESHOLD (CMOS)
CMOS-RS Low_off

LOGIC HIGH THRESHOLD (CMOS)
CMOS-RS High_on

The LOW trigger is much the same but the HIGH is a little higher than the unbranded.

So here we have the full results
results

This test wasn’t the greatest and it is only my interpretation of it. For example, should I have taken readings when the LED’s were at full illumination? Different people will prefer different things.
The unbranded probe didn’t seem to have that dimming of the LED’s depending on the voltage. It was clearly either ON or OFF. Whether this is a good or bad thing will depend on user preference. For me its not too good. This probe however is the only one to have the buzzer which is a nice thing to have sometimes.
I think for me the RS probe will now be my probe of choice. It has nice long leads, feels good to hold and use and the results were decent too.

 Posted by at 1:19 pm
Aug 292015
 

As Ive mentioned in my repair log of the Fluke 90 there is some useful functionality that is only available when connected to a PC.
These features appeal to me but I dont have an old PC lying around in order to use the ancient DOS program for this so I made my own.
What I do have is an RS232 to USB converter so I removed the DB25 connector and changed it for a standard 9 pin variety.
IMAG1493

With that made up I could quickly test it was correct by firing up a terminal window and sending any command. If successful the Fluke will display “REMOTE” on the LCD.

Here is the software I have been working on the last couple of days.
fluke90RC

Here it is all connected up to Breywood and working
IMAG1500
IMAG1498
IMAG1501

Its not finished yet and certain things will be tweaked and changed and added in time but I successfully tested it today and almost everything works great.
I still need to work on the UPLOAD and DOWNLOAD functionality but the tracing works fine which is what I was most interested in.

I cant imagine many/any people wanting this program but here it is anyway. It should be compatible with all the Fluke 90 devices. There are some CPU specific commands here which are included despite the fact I cannot test them.

It requires .NET 3.5 and should work on both 32bit and 64bit machines. Available in the ‘DOWNLOADS/SOFTWARE’ section

 Posted by at 11:22 am